Inteum Company
Links
seedsprint
Visible Legacy
RSS
News & Resources
Inteum Company News
Inteum Library
Subscribe
Search Results - implant
7
Results
Sort By:
Published Date
Updated Date
Title
ID
Descending
Ascending
A non-electronic reference
implant
for detection of implant loosening after joint replacement surgery
Joint replacement is an effective surgical intervention for some joint diseases.
Implant
loosening is a disabling condition that can affect patients after joint replacement surgery. Unfortunately, subtle progression of tissue deterioration around the implant remains a major challenge, because signs and symptoms may not be clinically apparent until...
Published: 12/9/2024
|
Inventor(s):
Hanna Dietrich
,
Joseph DiFranceisco
,
Miguel Isaga
,
Luke Austin
,
Erik Brewer
,
Hamid Seyyedhosseinzadeh
,
Mary Staehle
,
Ann DiGuglielmo
Keywords(s):
Arthroplasty
,
Implant
,
Joint
,
Radiography
,
Replacement
,
Surgery
Category(s):
Human Health Care > Medical Devices
,
Human Health Care > Biomarkers, Diagnosis and Detection
Bactericidal Biomedical Electrode Coatings that Enhances Charge Coupling
Atrial fibrillation (AFib or AF) is the most common type of heart arrhythmia afflicting millions of people throughout the world and leads to more than 166,000 deaths each year. Pacemakers and defibrillators are
implant
ed into over a million people every year and vital for preventing the adverse complications of AFib. However, implantation of these devices...
Published: 12/9/2024
|
Inventor(s):
Jeffrey Hettinger
,
Greg Caputo
,
Lia Yu
Keywords(s):
Antibacterial
,
Coatings
,
defibrillator
,
Electrode
,
Implant
,
pacemaker
Category(s):
Human Health Care > Medical Devices
,
Engineering > Materials
Antibacterial Coating for Dental
Implant
s
Reduces the Progression of Peri-
implant
Disease and Minimizes the Surface Degradation and Fracture Susceptibility of Dental CeramicsThis antibacterial coating for the titanium screw that attaches the new implant to the bone of the jaw reduces the progression of peri-implant disease, which can lead to bone loss and eventual loss of the implant. Implants...
Published: 2/22/2024
|
Inventor(s):
Christopher Batich
,
Fan Ren
,
Arthur Clark
,
Patrick Carey
,
Josephine Esquivel-Upshaw
Keywords(s):
Anti-bacterial
,
Bacterial
,
Coating
,
Dental
,
implant
Category(s):
Technology Classifications > Human Health Care > Others
,
Technology Classifications > Medical Devices > Equipment
A novel sealant device that aids in stem cell localization in the treatment of lower back pain
TechnologyOne of the major causes of lower back pain is intervertebral disc (IVD) degeneration also known as lumbar degenerative disc disease which often leads to disk herniation. IVD results from the dehydration of the central nucleus pulposus (NP) which ultimately alters the biomechanics of the disc and eventually causes tears to form in the peripheral...
Published: 12/9/2024
|
Inventor(s):
Andrea Vernengo
,
Thomas Christiani
,
Cristina Iftode
,
Jennifer Kadlowec
Keywords(s):
Back Pain
,
Biomaterials
,
Hydrogels
,
Implant
,
Polymers
,
Stem Cells
,
Tissue Engineering
Category(s):
Human Health Care > Biomaterials
,
Human Health Care > Medical Devices
,
Human Health Care > Therapeutics
A Sensitive and Accurate Diagnostic for Periprosthetic Joint Infection
Periprosthetic joint infection (PJI) is a devastating and costly complication following total hip replacement and total knee replacement. With the increase in the number of total joint replacements procedures performed annually, the number of complications involving revision surgery are also on the rise. PJI often results in
implant
failure and places...
Published: 12/9/2024
|
Inventor(s):
Alisina Shahi
Keywords(s):
Assesments
,
Diagnostics
,
Hip Replacement
,
Implant
,
Infection
,
Joint
,
Knee Replacement
,
Orthopedics
Category(s):
Human Health Care > Medical Devices
,
Human Health Care > Biomarkers, Diagnosis and Detection
Wireless Power Array for Efficient Energy Transfer to Biomedical
Implant
s
Ensures Stable Energy Transfer from Chargers to
Implant
s Even When MisalignedThis transmitter array configuration efficiently transfers energy to biomedical implants no matter the alignment between the charger’s transmitter coils and the implant’s receiver coils. Biomedical implants are devices that either replace a biological structure...
Published: 7/18/2023
|
Inventor(s):
Lawrence Fomundam
,
Jenshan Lin
Keywords(s):
Diabetes
,
implant
,
Misalignment Factor
,
Power Transfer Efficiency
,
sensor
,
Transmitter Array
,
Wireless Power Transfer
Category(s):
Technology Classifications > Engineering > Electrical
,
Technology Classifications > Medical Devices > Equipment
Use of Silver-containing Layers in and on
Implant
Surfaces
BackgroundMedical devices
implant
ed in the human body can react with internal bio fluids and cause infection or compromise the health of surrounding bone and/or tissue. Treating infections with antibiotics is not always desired because it can be difficult to direct the antibiotic to the specifically needed location, treatment can take between 3 to 14...
Published: 12/9/2024
|
Inventor(s):
Greg Caputo
Keywords(s):
Antimicrobial
,
Biomedical
,
Coatings
,
Implant
,
Medical Devices
Category(s):
Human Health Care > Biomaterials
,
Human Health Care > Medical Devices